CX20A-NA-3N Aichi Tokei Denki, CX20A-NA-3N Aichi Tokei , Aichi Tokei Vietnam
| 100% JAPAN Origin | Aichi tokei denki Vietnam | MODEL: CX20A-NA-3N (with 3m connection cable) Capacitive Electromagnetic Flow Monitor NPN output, without bracket |
| 100% JAPAN Origin | Aichi Tokei Denki Vietnam | Model: CX20A-PV-3B (with 3m connection cable) Capacitive Electromagnetic Flow Monitor PNP output, with bracket (screws x 4 pcs included) |
Specifications
| Model | CX | |||
|---|---|---|---|---|
| Nominal Diameters Accuracy-Guaranteed Flow-Rate Range |
10 | 15 | 20 | |
| 0.5 ~ 15 L/min | 2.0 ~ 60 L/min | |||
| Displayable Flow-Rate Range | 0.0 ~ 18 L/min | 0.0 ~ 72 L/min | ||
| Low-Flow Cut-Off | 0.45 L/min | 1.8 L/min | ||
| Repeatability Accuracy | ±2%F.S. (No need of straight piping) | |||
| Temperature Characteristics |
Ambient Temperature | ±5%F.S. (Relative error when changing from the standard temperature 25°C to 10°C or 50°C) | ||
| Fluid Temperature | ±5%F.S. (Relative error when changing from the standard temperature 25°C to 1°C or 85°C) | |||
| Piping Connection | Rc3/8 | Rc1/2 | Rc3/4 | |
| Fluid Temperature Range | 0 ~ 85°C | |||
| Conductivity Range | 5μS/cm ~ 3mS/cm | |||




Ms Thanh